secure the conductor, making certain that the terminal grips the wire, not the insulation. Ensure that
all wiring meets applicable local and national codes and requirements.
5.3.3 Power Wiring Diagram
MPC VECTOR Drive
Terminal
Single Phase 208/230 VAC Three Phase 208/230 VAC
L1 Line 1 Line 1
L2 N/C Line 2
L3 Line 2 Line 3
Ground Plate Ground Ground
Table 2 – AC Drive Terminals
Figure 3 – AC Power Connections
Wait a minimum of 5 minutes after disconnecting power before servicing the MPC VECTOR or pump motor.
Capacitors retain a charge even after power is removed from the controller.