1.3 Standard Reagent Head Assembly
Figure 3
The typical reagent head assembly consists of reagent head, diaphragm, and suction and
discharge check valves. This assembly is the only part of the pump to contact the process liquid;
consequently, maintenance is critical to pump performance. For most pump configurations,
suction and discharge check valve components are identical.