PULSAlarm
Leak Detection
Vacuum and Pressure Options
For PULSA Series Metering Pumps
Models 680, 880, 7120, 7440, 7660, and 8480
Installation, Operation & Maintenance Instruction
Bulletin #: IOM–PSVLD-03 Rv B
Manufacturers of Quality Pumps,
Controls and Systems
ENGINEERED PUMP OPERATIONS
2883 Brighton Henrietta Townline Road
Rochester, New York, 14623
Telephone (585) 292-8000
Fax (585) 424-5619
www.pulsa.com E-mail:pulsa@idexcorp.com
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - PULSAlarm

PULSAlarm Leak Detection Vacuum and Pressure Options For PULSA Series Metering Pumps Models 680, 880, 7120, 7440, 7660, and 8480 Installation, Op

Page 2 - Copyright

10 4. Setup for Pressure Pumps incorporating pressure leak detection are shipped from the factory with the system fully set up to work at full pum

Page 3 - Table of Contents

11 To set up Pressure: 1. Complete re-assembly of the diaphragm, reagent head, and external components if they were taken apart. Ensure that reag

Page 4 - Conventions:

12 4. The method used to prime the system will vary with the chosen barrier fluid. The fluid must be introduced under pressure on the inlet side.

Page 5 - 1. System Information

13 14. In order to fully balance and evacuate the leak detection system, the pump must now run at normal discharge pressure for a period of about 30

Page 6 - 1.2 PULSAlarm Reagent Head

14 4.1 Pressure fill chamber Under certain conditions, when barrier fluids other than water are used, a pressure chamber can be fabricated from re

Page 7 - 1.4 Diaphragm Construction

15 1. Connect a vacuum pump to the top fitting of the fluid fill device. Open BOTH valves on the device. 2. Place the lower fill tube into the c

Page 8 - 2. Electrical

16 5. Maintenance Although the PULSAlarm leak detection system requires minimal maintenance, vacuum must be maintained to prevent false alarms an

Page 9 - Setup for Vacuum system

17 5.2 PULSAlarm Diaphragm Maintenance Figure 10 – diaphragm and head orientation 5.2.1 PULSAlarm Diaphragm Removal Use the following procedu

Page 10 - 4. Setup for Pressure

18 5.2.2 Inspection Remove and inspect the diaphragm assembly. It may have taken a permanent convex/concave set as a result of normal flexure and

Page 11

19 5.3 Leak Detection system conversion Leak detection system conversion information can be found in Bulletin CV-LD-0203 (vacuum to pressure syste

Page 12 - Open to

2 Pulsafeeder Factory Service Policy Should you experience a problem with your Pulsafeeder pump, first consult the troubleshooting guide in your op

Page 13

20 Medical Conditions Aggravated by Exposure No known applicable information. The above listed potential effects of overexposure are based on actua

Page 14 - 4.1 Pressure fill chamber

21 Component Exposure Limits There are no components with workplace exposure limits. Engineering Controls Local Ventilation: None should be needed

Page 15

22 unless generated as an aerosol. Water: This product has a very low water solubility (< 100 ppb). As it has a specific gravity of < 1, if d

Page 16 - 5. Maintenance

23 Section 304 CERCLA Hazardous Substances: None. Section 312 Hazard Class: Acute: No Chronic: No Fire: No Pressure: No Reactive: N

Page 17

24 IOM–PSVLD-03 Rev B Eng inee r ed P um p Ope r a t io n s PU LS Al a rm

Page 18 - 5.2.2 Inspection

3 Table of Contents 1. SYSTEM INFORMATION...5 1.1 D

Page 19 - 6. Silicone Fluid MSDS

4 Conventions: . A WARNING DEFINES A CONDITION THAT COULD CAUSE DAMAGE TO BOTH THE EQUIPMENT AND THE PERSONNEL OPERATING IT. PAY CLOSE ATTENTION

Page 20

5 For information on overall pump operation and maintenance, refer to the Installation, Operation, and Maintenance manual specific to the model of p

Page 21

6 1.2 PULSAlarm Reagent Head The PULSAlarm leak detection reagent head assembly consists of reagent head, leak detection diaphragm, suction and d

Page 22

7 1.4 Diaphragm Construction The adhesive rings aid in assembly and are not present for sealing purposes. Figure 2 – diaphragm construct

Page 23

2. Electrical Figure 3 – switch and housing If equipped with an optional pressure switch, install electrical wiring and conduit in accordance wit

Page 24

9 3. Setup for Vacuum system A vacuum must be maintained at all times during pump operation, otherwise, the diaphragm halves may separate during